Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Heart Rhythm ; 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38336193

RESUMO

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.

2.
Int J Biol Macromol ; 253(Pt 5): 127073, 2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-37774824

RESUMO

Leishmania donovani is the causative unicellular parasite for visceral leishmaniasis (VL); and FeS proteins are likely to be very essential for their survival and viability. Cytosolic FeS cluster assembly (CIA) machinery is one of the four systems for the biosynthesis and transfer of FeS clusters among eukaryotes; Cfd1 and Nbp35 are the scaffold components for cytosolic FeS cluster biogenesis. We investigated the role of CIA machinery components and purified Cfd1 and Nbp35 proteins of L. donovani. We also investigated the interactive nature between LdCfd1 and LdNbp35 proteins by in silico analysis, in vitro co-purification, pull down assays along with in vivo immuno-precipitation; which inferred that both LdCfd1 and LdNbp35 proteins are interacting with each other. Thus, our collective data revealed the interaction between these two proteins which forms a stable complex that can be attributed to the cellular process of FeS clusters biogenesis, and transfer to target apo-proteins of L. donovani. The expression of Cfd1 and Nbp35 proteins in Amp B resistant parasites is up-regulated leading to increased amount of FeS proteins. Hence, it favors increased tolerance towards ROS level, which helps parasites survival under drug pressure contributing in Amphotericin B resistance.


Assuntos
Proteínas Ferro-Enxofre , Leishmania donovani , Proteínas de Saccharomyces cerevisiae , Leishmania donovani/metabolismo , Proteínas de Saccharomyces cerevisiae/metabolismo , Proteínas de Ligação ao GTP
3.
Arrhythm Electrophysiol Rev ; 11: e19, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36304202

RESUMO

Pacemakers are a key technology in the treatment of bradyarrhythmias. Leadless pacemakers (LP) were introduced to address limitations of transvenous devices. However, guidelines and other restrictions have led to LPs becoming niche products. The aim of this consensus statement was to determine the strength of opinion of UK implantation experts as to how LPs can be more optimally used. Using a modified Delphi approach, a panel of LP experts developed 36 statements that were used to form a survey that was distributed to LP implanters in the UK. Stopping criteria included a 3-month window for response, a minimum 25% response rate and at least 75% of statements achieving the threshold for consensus (agreed at 66%). In all, 31 of 36 statements reached consensus, and 23 of these achieved ≥90% agreement. Five statements did not achieve consensus. On the basis of these results, seven recommendations were proposed. The implementation of these recommendations may increase the use of LPs, with the aim of improving patient outcomes.

4.
ESC Heart Fail ; 9(1): 48-56, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34882989

RESUMO

AIMS: The CardioMEMS HF System Post-Market Study (COAST) was designed to evaluate the safety, effectiveness, and feasibility of haemodynamic-guided heart failure (HF) management using a small sensor implanted in the pulmonary artery of New York Heart Association (NYHA) Class III HF patients in the UK, Europe, and Australia. METHODS AND RESULTS: COAST is a prospective, international, multicentre, open-label clinical study (NCT02954341). The primary clinical endpoint compares annualized HF hospitalization rates after 1 year of haemodynamic-guided management vs. the year prior to sensor implantation in patients with NYHA Class III symptoms and a previous HF hospitalization. The primary safety endpoints assess freedom from device/system-related complications and pressure sensor failure after 2 years. Results from the first 100 patients implanted at 14 out of the 15 participating centres in the UK are reported here. At baseline, all patients were in NYHA Class III, 70% were male, mean age was 69 ± 12 years, and 39% had an aetiology of ischaemic cardiomyopathy. The annualized HF hospitalization rate after 12 months was 82% lower [95% confidence interval 72-88%] than the previous 12 months (0.27 vs. 1.52 events/patient-year, respectively, P < 0.0001). Freedom from device/system-related complications and pressure sensor failure at 2 years was 100% and 99%, respectively. CONCLUSIONS: Remote haemodynamic-guided HF management, using frequent assessment of pulmonary artery pressures, was successfully implemented at 14 specialist centres in the UK. Haemodynamic-guided HF management was safe and significantly reduced hospitalization in a group of high-risk patients. These results support implementation of this innovative remote management strategy to improve outcome for patients with symptomatic HF. Clinical registration number: ClinicalTrials.gov identifier: NCT02954341.


Assuntos
Insuficiência Cardíaca , Medicina Estatal , Idoso , Idoso de 80 Anos ou mais , Monitorização Ambulatorial da Pressão Arterial/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reino Unido/epidemiologia
5.
J Cardiovasc Electrophysiol ; 33(1): 102-108, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34783107

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) is rising in parallel to cardiac implantable electronic device implantations. Persistent left side superior vena cava (PLSVC) is a relatively common anatomical variant in the healthy population; TLE in patients with a PLSVC is rare. METHOD: Data were collated from 6 European TLE institutes of 10 patients who had undergone lead extraction with a PLSVC. Patient demographics, procedural challenges and outcomes were reported. RESULTS: Ten patients aged 73.4 ± 7.8 years (60% male) underwent TLE of 20 leads (3 left ventricle, 10 right ventricle, 7 right atrium) with dwell time of 82.95 ± 39.1 months. Of the 10 cases, 4 had an infection indication and 5 were biventricular system extractions; 25% of the extracted leads were defibrillator leads. The majority of the procedures were completed in the cardiac catheterization suite (80%) under general anaesthesia (60%) by cardiologists (80%) using a rotational powered sheath (65%). The Tandem approach was used successfully in 3 cases. Complete procedural success was obtained in 100% of cases in the absence of complications within 127.4 ± 74.7 min. There was no 30-day mortality. CONCLUSION: TLE in PLSVC is feasible albeit rare. Standard extraction techniques in experienced hands are associated with favorable outcomes; the Tandem procedure may be an additional technique to improve the safety and efficacy of TLE in PLSVC.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Veia Cava Superior Esquerda Persistente , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Feminino , Humanos , Masculino , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia
6.
Heart Rhythm O2 ; 2(5): 463-471, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34667961

RESUMO

BACKGROUND: High adherence to remote monitoring (RM) in pacemaker (PM) patients improves outcomes; however, adherence remains suboptimal. Bluetooth low-energy (BLE) technology in newer-generation PMs enables communication directly with patient-owned smart devices using an app without a bedside console. OBJECTIVE: To evaluate the success rate of scheduled RM transmissions using the app compared to other RM methods. METHODS: The BlueSync Field Evaluation was a prospective, international cohort evaluation, measuring the success rate of scheduled RM transmissions using a BLE PM or cardiac resynchronization therapy PM coupled with the MyCareLink Heart app. App transmission success was compared to 3 historical "control" groups from the Medtronic de-identified CareLink database: (1) PM patients with manual communication using a wand with a bedside console (PM manual transmission), (2) PM patients with wireless automatic communication with the bedside console (PM wireless); (3) defibrillator patients with similar automatic communication (defibrillator wireless). RESULTS: Among 245 patients enrolled (age 64.8±15.6 years, 58.4% men), 953 transmissions were scheduled through 12 months, of which 902 (94.6%) were successfully completed. In comparison, transmission success rates were 56.3% for PM manual transmission patients, 77.0% for PM wireless patients, and 87.1% for defibrillator wireless patients. Transmission success with the app was superior across matched cohorts based on age, sex, and device type (single vs dual vs triple chamber). CONCLUSION: The success rate of scheduled RM transmissions was higher among patients using the smart device app compared to patients using traditional RM using bedside consoles. This novel technology may improve patient engagement and adherence to RM.

7.
ESC Heart Fail ; 8(5): 3906-3916, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34382749

RESUMO

AIMS: This study aims to establish the feasibility, safety, and efficacy of outpatient intravenous (IV) diuretic treatment for the management of decompensated heart failure (HF) for patients enrolled in the HeartFailure@Home service. METHODS AND RESULTS: We retrospectively analysed the clinical episodes of decompensated HF for patients enrolled in the HeartFailure@Home service, managed by ambulatory IV diuretic treatment either at home or on a day-case unit. A control group consisting of HF patients admitted to hospital for IV diuretics (standard-of-care) was also evaluated. In total, 203 episodes of decompensated HF (n = 154 patients) were evaluated. One hundred and fourteen episodes in 79 patients were managed exclusively by the ambulatory IV diuretic service-78 (68.4%) on a day-case unit and 36 (31.6%) domiciliary; 84.1% of patient episodes under the HF@Home service were successfully managed entirely in an out-patient setting without hospitalization. Eleven patients required admission in order to administer higher doses of IV diuretics than could be provided in the ambulatory setting. During follow-up, there were 20 (17.5%) 30 day re-admissions with HF or death in the ambulatory IV group and 29 (32.6%) in the standard-of-care arm (P = 0.02). There was no difference in 30 day HF readmissions between the two groups (14.9% ambulatory vs. 13.5% inpatients, P = 0.8), but 30 day mortality was significantly lower in the ambulatory group (3.5% vs. 21.3% inpatients, P < 0.001). CONCLUSIONS: Outpatient ambulatory management of decompensated HF with IV diuretics given either on a day case unit or in a domiciliary setting is feasible, safe, and effective in selected patients with decompensated HF. This should be explored further as a model in delivering HF services in the outpatient setting during COVID-19.


Assuntos
COVID-19 , Insuficiência Cardíaca , Furosemida , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Estudos Retrospectivos , SARS-CoV-2 , Resultado do Tratamento
8.
Eur Heart J Case Rep ; 5(7): ytab219, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34377899

RESUMO

BACKGROUND: The use of transvenous pacing leads is associated with the risk of developing tricuspid valve (TV) dysfunction. This develops through several mechanisms including the failure of leaflet coaptation or direct damage to the TV or to its sub-valvular apparatus and can result in significant tricuspid regurgitation (TR). Multiple approaches to pacemaker implantation after transvenous lead extraction (TLE) or surgical TV repair have been described. Placement of pacing leads across the TV is generally avoided in such circumstances. CASE SUMMARY: A 66-year-old woman presented with a year-long history of exertional dyspnoea, peripheral oedema, and postural neck pulsations. Her medical history included a dual-chamber pacemaker implantation for sinus node dysfunction 14 years ago. Echocardiography revealed severe lead-related TR. Her case was discussed in our multi-disciplinary team meeting. A decision was made to perform a TLE and implant a leadless pacemaker in an attempt to avoid open-heart surgery if possible. This was reserved as an option in the event of persistent severe TR. Transvenous extraction of the right ventricular lead was performed. The atrial lead was preserved and connected to and AAI device. A Micra AV was implanted allowing for atrioventricular (AV) synchronous pacing. DISCUSSION: We present the first case of successful implementation of AV sequential pacing using a dual-pacemaker approach involving the use of an AAI pacemaker and a Micra AV device. This was performed after TLE for severe lead-related TR.

9.
Heart Int ; 15(2): 103-105, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-36277832

RESUMO

Lead displacement is a common complication of pacemaker device implantation, often resulting in prolonged hospital stays and increased costs. The frequency of long-term lead displacement ranges between 1.8% and 8.0%. In our case, the patient did not present any symptoms and the lead displacement was seen at a relatively late stage. During a routine pacemaker follow up, it was noted that the right ventricular (RV) threshold had increased and deteriorated over time. The pacemaker box had rotated anticlockwise and the RV lead had developed a loop that eventually led to its retraction from the RV implantation position into the pulmonary artery. The patient was asymptomatic; however, he underwent RV lead revision. Patient education, opening an appropriate pocket for the size of the generator, fixing the sleeves to an appropriate tightness and securing the battery with a strong suture all can be used to avoid lead displacement.

10.
ESC Heart Fail ; 7(1): 107-116, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31794140

RESUMO

AIMS: Remote monitoring of patients with physiological data derived from cardiac implanted electronic devices (CIEDs) offers potential to reconfigure clinical services. The 'Heart Failure Risk Score' (HFRS) uses input from integrated device physiological monitoring to risk-stratify patients as low-risk, medium-risk, or high-risk of a heart failure event in the next 30 days. This study aimed to evaluate a novel clinical pathway utilizing a combination of CIED risk-stratification and telephone triage to identify patients with worsening heart failure (WHF). METHODS AND RESULTS: A prospective, single-centre, real-world evaluation of the 'Triage-HF Plus' clinical pathway (HFRS in combination with telephone triage) over a 27 month period. One hundred and fifty-seven high-risk HFRS transmissions were referred for telephone triage assessment. Interventions were at the discretion of the clinical assessor acting in accordance with clinical guidelines. An additional 3month consecutive sample of low and medium HFRS transmissions (control group) were also contacted for telephone triage assessment (n = 98). Successful telephone contact was made in 127 (81%) of referred high-risk HFRS cases: 71 (55.9%) were confirmed to have WHF requiring intervention; 19 (14.9%) had an alternative acute medical problem; one patient had been recently discharged from hospital with WHF; and 36 (28.0%) had no apparent cause for the high score. In the control group, only one patient had symptoms of WHF. The sensitivity and specificity of CIED-based remote monitoring to identify WHF 98.6% (92.5-100.0%) and 63.4% (55.2-71.0%), respectively. CONCLUSIONS: The Triage-HF Plus clinical pathway is a potentially useful remote monitoring tool for patients with heart failure and in situ CIEDs.


Assuntos
Cardiopatias Congênitas , Insuficiência Cardíaca , Triagem , Adulto , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Estudos Prospectivos , Encaminhamento e Consulta , Estudos Retrospectivos , Telefone
11.
Int J Cardiol Heart Vasc ; 23: 100349, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30976654

RESUMO

BACKGROUND: The use of pacemakers in the treatment of cardioinhibitory vasovagal syncope is controversial with a mixed message from the limited evidence base. Single chamber leadless pacemakers have been shown to be an effective alternative option to conventional pacemakers. OBJECTIVE: This study examines the use of leadless pacemakers in a cardioinhibitory vasovagal population in the United Kingdom. METHODS: Observational data on 32 patients implanted with the Micra Transcatheter Pacemaker System for vasovagal syncope are presented. Data was collected on implant indications, implant procedure and follow up data from 12 centres across the United Kingdom that had elected to use a Micra leadless pacemaker in this patient population. RESULTS: 32 patients aged 37 ±â€¯14 years (range 18 to 64 years) with 62% of the patients being female were recruited to the study. Vasovagal syncope was diagnosed clinically and with the support of Holter monitoring, tilt table testing and implantable loop recorders. The duration of symptoms was 8 ±â€¯8 yrs. with an average frequency of syncope being 4 ±â€¯6 times/year. The Micra pacemaker was successfully implanted in all patients with a major complication rate of 3.1%. Patients were followed up for 404 ±â€¯237 days (range 63-928 days). At follow up 28 (87%) patients were free from symptoms. CONCLUSIONS: This observational study suggests that the use of a single chamber leadless pacemaker in the treatment of cardioinhibitory vasovagal syncope might be a reasonable clinical option.

13.
PLoS One ; 14(1): e0206611, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30601808

RESUMO

BACKGROUND: There are limited reports outlining the financial cost of treating cardiac implantable electronic device (CIED) infection outside the United States. This study aimed to determine the average treatment cost of CIED infection in a large UK tertiary referral centre and compared costs of different treatment pathways that are recognised in the management of CIED infection (early versus delayed re-implantation). METHODS: We retrospectively analysed cost and length of stay (LOS) data for consecutive patients undergoing infected CIED extraction with cardiac resynchronization therapy (CRT-D [with defibrillator], CRT-P [with pacemaker]), implantable cardioverter-defibrillators (ICDs) and permanent pacemakers (PPMs). RESULTS: Between January 2013 and March 2015, complete data was available for 84 patients (18 [21.4%] CRT-D, 24 [28.6%] ICDs and 42 [50.0%] PPMs). When all cases were considered the cost of infection ranged from £5,139 (PPM) to £24,318 (CRT-D). Considering different treatment strategies; 41 (48.8%) underwent CIED extraction and re-implantation during the same admission (early re-implant strategy (ER). 43 (51.2%) underwent extraction, but were then discharged home to be re-admitted for day-case re-implantation (delayed re-implant strategy (DR)). Median LOS was significantly shorter in DR compared to ER (5.0 vs. 18.0 days, p<0.001). The total cost of CIED infection episode was similar for both treatment strategies (median £14,241.48 vs. £14,741.70 including wearable defibrillator (Lifevest) and outpatient antibiotics costs, ER vs. DR; p = 0.491). CONCLUSION: CIED infections are expensive and associated with significant health-economic burden. When all device types were considered, a DR strategy is associated with reduced LOS without an increased cost penalty.


Assuntos
Efeitos Psicossociais da Doença , Remoção de Dispositivo/economia , Cardiopatias/terapia , Tempo de Internação/estatística & dados numéricos , Infecções Relacionadas à Prótese/economia , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca/economia , Remoção de Dispositivo/efeitos adversos , Feminino , Custos de Cuidados de Saúde/estatística & dados numéricos , Humanos , Tempo de Internação/economia , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/terapia , Retratamento/economia , Retratamento/métodos , Retratamento/estatística & dados numéricos , Estudos Retrospectivos , Centros de Atenção Terciária/economia , Centros de Atenção Terciária/estatística & dados numéricos , Fatores de Tempo , Reino Unido
14.
J Cardiovasc Electrophysiol ; 30(4): 569-574, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30661279

RESUMO

INTRODUCTION: Leadless pacemakers may provide a safe and attractive pacing option to patients with cardiac implantable electronic device (CIED) infection. We describe the characteristics and outcomes of patients with a recent CIED infection undergoing Micra implant attempt. METHODS AND RESULTS: Patients with prior CIED infection and device explant with Micra implant within 30 days, were identified from the Micra post approval registry. Procedure characteristics and outcomes were summarized. A total of 105 patients with prior CIED infection underwent Micra implant attempt ≤30 days from prior system explant (84 [80%] pacemakers and 13 [12%] ICD/CRT-D). All system components were explanted in 93% of patients and explant occurred a median of 6 days before Micra implant, with 37% occurring on the day of Micra implant. Micra was successfully implanted in 99% patients, mean follow-up duration was 8.5 ± 7.1 months (range 0-28.5). The majority of patients (91%) received IV antibiotics preimplant, while 42% of patients received IV antibiotics postprocedure. The median length of hospitalization following Micra implant was 2 days (IQR, 1-7). During follow-up, two patients died from sepsis and four patients required system upgrade, of which two patients received Micra to provide temporary pacing support. There were no Micra devices explanted due to infection. CONCLUSION: Implantation of the Micra transcatheter pacemaker is safe and feasible in patients with a recent CIED infection. No recurrent infections that required Micra device removal were seen. Leadless pacemakers appear to be a safe pacing alternative for patients with CIED infection who undergo extraction.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Remoção de Dispositivo , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/terapia , Administração Intravenosa , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/administração & dosagem , Estimulação Cardíaca Artificial/mortalidade , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/mortalidade , Desenho de Equipamento , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Int J Biol Macromol ; 116: 1128-1145, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29782976

RESUMO

The pathogenicity of protozoan parasites is frequently attributed to their ability to circumvent the deleterious effects of ROS and Fe-S clusters are among their susceptible targets with paramount importance for parasite survival. The biogenesis of Fe-S clusters is orchestrated by ISC system; the sulfur donor IscS and scaffold protein IscU being its core components. However, among protozoan parasites including Leishmania, no information is available regarding biochemical aspect of IscU, its interaction partners and regulation. Here, we show that Leishmania donovani IscU homolog, LdIscU, readily assembles [2Fe-2S] clusters and, interestingly, follows Michaelis-Menten enzyme kinetics. It is localized in the mitochondria of the parasite and interacts with LdIscS to form a stable complex. Additionally, LdIscU and Fe-S proteins activity is significantly upregulated in resistant isolates and during stationary growth stage indicating an association between them. The differential expression of LdIscU modulated by Fe-S proteins demand suggests its potential role in parasite survival and drug resistance. Thus, our study provides novel insight into the Fe-S scaffold protein of a protozoan parasite.


Assuntos
Resistência a Medicamentos , Regulação da Expressão Gênica , Proteínas Ferro-Enxofre/biossíntese , Leishmania donovani/metabolismo , Proteínas de Protozoários/biossíntese , Animais , Proteínas Ferro-Enxofre/química , Proteínas Ferro-Enxofre/genética , Leishmania donovani/química , Leishmania donovani/genética , Masculino , Proteínas de Protozoários/química , Proteínas de Protozoários/genética , Coelhos
18.
Mol Immunol ; 97: 33-44, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29558698

RESUMO

We report here a Leishmania donovani ornithine decarboxylase (Ld-ODC) gene used as a DNA vaccine against visceral leishmaniasis in a murine Balb/c mouse model. This study also evaluated the possible mechanism of action directed by this candidate. We found a Th1 immune response after immunization using an Ld-ODC DNA vaccine, with results based on the rearrangement of TCR-V-α-2, proliferation of Carboxy fluorescein Succinimidyle ester positive T cells, which were able to produce cytokines such as TNF-α, IFN-γ, IL-12 and IL-2, but not IL-4, IL-5, IL-6 and IL-10, and modulations of the STAT-1 and p38 MAP kinase signaling pathways. The results were corroborated with the reduction in the amastigote proliferation and parasite killing in spleens after infection in vitro. We conclude this study suggesting that the Ld-ODC DNA construct could be a new vaccine candidate against visceral leishmaniasis.


Assuntos
Imunomodulação , Leishmania donovani/imunologia , Vacinas contra Leishmaniose/uso terapêutico , Leishmaniose Visceral/prevenção & controle , Ornitina Descarboxilase/imunologia , Vacinas de DNA/uso terapêutico , Imunidade Adaptativa/fisiologia , Animais , Células Cultivadas , Modelos Animais de Doenças , Imunização/métodos , Imunomodulação/genética , Imunomodulação/imunologia , Leishmania donovani/genética , Vacinas contra Leishmaniose/imunologia , Leishmaniose Visceral/imunologia , Leishmaniose Visceral/patologia , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Ornitina Descarboxilase/genética , Vacinas de DNA/imunologia
19.
Can J Cardiol ; 33(8): 1066.e5-1066.e7, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28754393

RESUMO

Subcutaneous implantable cardioverter defibrillators (S-ICDs) provide effective defibrillation, while also reducing the risk of long-term lead problems. However, S-ICDs do not offer bradycardia or antitachycardia pacing and therefore use has been limited. Combined implantation of an S-ICD with a leadless pacemaker (LP) has been proposed to overcome this limitation. Although a handful of combined S-ICD/LP implantations have been reported for Nanostim (St Jude Medical, St Paul, MN) as well as Micra LP (Medtronic, Minneapolis, MN) systems, none have documented delivery of appropriate shock therapies for spontaneous ventricular tachycardia. We report the first case of effective defibrillation for spontaneous ventricular tachycardia in a patient with combined Micra LP and S-ICD.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Marca-Passo Artificial , Taquicardia Ventricular/terapia , Idoso de 80 Anos ou mais , Desenho de Equipamento , Humanos , Masculino , Taquicardia Ventricular/fisiopatologia
20.
Heart ; 103(17): 1315-1322, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28687562

RESUMO

BACKGROUND: Subcutaneous implantable cardioverter defibrillators (S-ICDs) are considered an alternative to conventional transvenous ICDs (TV-ICDs) in patients not requiring pacing. METHODS: We searched MEDLINE and EMBASE for studies evaluating efficacy and safety outcomes in S-ICD patients. Outcomes were pooled across studies. RESULTS: Sixteen studies were included with 5380 participants (mean age range 33-56 years). Short-term follow-up data were available for 1670 subjects. The most common complication was pocket infection, affecting 2.7%. Other complications included delayed wound healing (0.6%) and wound discomfort (0.8%). 3.8% of S-ICDs were explanted, most commonly for pocket infection. Mortality rates in hospital (0.4%) and during follow-up (3.4% from 12 studies reporting) were low. Incidence of ventricular arrhythmia varied from 0% to 12%. Overall shock efficacy exceeded 96%. Inappropriate shocks affected 4.3% and was most commonly caused by T-wave oversensing. CONCLUSIONS: Although long-term randomised data are lacking, observational data suggest similar shock efficacy and short-term complication rates between the S-ICD and TV-ICD.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Desenho de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...